Technical Specifications
5.2 Failsafe Alarm Relay Specifications
5.2
Failsafe Alarm Relay Specifications
Hazardous Environments
Maximum Switching Voltage
Rated
Switching
Current
Isolation
30 VDC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
250 VAC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
50 to 60 Hz for 1 minute
Non-Hazardous Environment
Maximum Switching Voltage
Rated
Switching
Current
Isolation
30 VDC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
250 VAC
2 A
5.0 kVAC
between coil and contacts
1.0 kVAC
between contacts
50 to 60 Hz for 1 minute
5.3
Supported Networking Standards
The following networking standards are supported by RUGGEDCOM RST916C:
Standard
10 Mbps
100
Mbps
1000
Mbps
10000
Mbps
Description
IEEE 802.1AB
•
•
•
•
Link Layer Discovery
Protocol (LLDP)
IEEE 802.1D
•
•
•
•
MAC bridges, Spanning
Tree Protocol (STP)
IEEE 802.1Q
•
•
•
•
VLAN (Virtual LAN)
IEEE 802.1Q-2005
•
•
•
•
Multiple Spanning
Tree Protocol (MSTP)
IEEE 802.1w
•
•
•
•
Rapid Spanning
Tree Protocol (RSTP)
IEEE 802.1p
•
•
•
•
Class of Service (CoS)
IEEE 802.1x
•
•
•
•
Port-based network
access control
IEEE 802.3
•
10Base-T
IEEE 802.3u
•
100Base-TX/100Base-FX
IEEE 802.3z
•
1000Base-SX/LX
28
RUGGEDCOM RST916C
Installation Manual, 04/2021, C79000-G8976-1490-03