Description of the device
2.5 SET button
SCALANCE M826
26
Operating Instructions, 08/2018, C79000-G8976-C362-05
You will find more information in the section "Service and Maintenance" in the
SCALANCE M-800 Web Based Management configuration manual.
●
Reset to factory defaults
–
Hold down the button until the red fault LED (F) stops flashing after approximately 10
seconds and is permanently lit.
–
Now release the button and wait until the fault LED (F) goes off again. The device then
starts automatically with the factory settings. By resetting to the factory configuration
settings, the device loses its configured IP address. Since the device does not have a
configured IP address, you need to assign an IP address e.g. via a DHCP server or
using the Primary Setup Tool
You will find more information in the SCALANCE M-800 Web Based Management
configuration manual.
WARNING
EXPLOSION HAZARD
Do not press the SET button if there is a potentially explosive atmosphere.