● Time
Select the setting from the drop-down list. The following settings are possible:
– Manual
The system time is set manually. You can configure other settings in "System > System
Time > Manual Setting".
– SIMATIC Time
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
– SNTP Client
The system time is set via an SNTP server. You can configure other settings in "System
> System Time > SNTP Client".
– NTP Client
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
● SNMP
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
– SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
– SNMPv3
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
● SNMPv1/v2 Read Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
● SNMPv1 Traps
Enable or disable the sending of SNMPv1 traps (alarm frames). You can configure other
settings in "System > SNMP > Traps".
● SINEMA Configuration Interface
If the SINEMA configuration interface is enabled, you can download configurations to the
device using STEP 7 Basic / Professional.
● DHCP Client
Enable or disable the DHCP client. You can configure other settings in "System > DHCP".
● DUID Type
Specify which DUID type is used. The DUID types are defined in RFC 3315.
– DUID-LLT
DUID is based on the link layer address of the interface and a time stamp
– DUID-EN
DUID is assigned by the vendor (EN = enterprise number)
– DUID-LL
DUID is based on the link layer address of the interface
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
116