The "Group" table contains the following columns:
● Group Identifier
Index of the group.
● Name
Specify a name for the group. The entry is displayed in the "Action" table as column name.
● Source Interface
Specify the interface via which reachability of the destination addresses is monitored.
● Interval
Specify the interval at which the ping tests take place.
● TTL (Time to live)
Specify the TTL value.
● Retries
Specify how often the ping attempt is repeated.
The time interval between the ping attempts is 100 ms. With a large number of ping
attempts, this can result in a time delay.
If none of the configured addresses responds, the ping test is considered to have failed
(error). In the "Action" table, you define whether a specific action is executed.
● 1. - 3. Ping destination
Specify the destination address that is used as reference for the reachability.
The "Group" table contains the following columns:
● Group 1 - 5
If a name if configured, it is used as column name. Assign the groups to the desired
interface. The interface is considered reachable when all assigned groups are reachable. If
only one of the groups is not reachable, the configured action is executed on the selected
interface.
● Action for
Indicates the interface on which the action is executed.
● 1st action - 5th action
The following actions are possible:
– None (default)
– Restart
Restart the device. After the restart, the device waits for 10 minutes and then sends a
ping to the first destination address.
– Soft-Reset (only with M87x)
Restart of the mobile wireless engine via the software
– Hard-Reset (only with M87x)
Restart of the mobile wireless engine
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
208
Configuration Manual, 11/2019, C79000-G8976-C388-08