Description
The page contains the following:
● User Account
Enter the name for the user. The name must meet the following conditions:
– It must be unique.
– It must be between 1 and 250 characters long.
– The following characters must not be included: § ? " ; :
– The characters for Space and Delete also cannot be included.
Note
User name cannot be changed
After creating a user, the user name can no longer be modified.
If a user name needs to be changed, the user must be deleted and a new user created.
Note
User names: admin
You can configure the device with this user name.
When you log in for the first time or log in after a "Restore Factory Defaults and Restart", you
will be prompted to change the predefined password "admin". You can also rename the
"admin" user preset in the factory once. Afterwards, renaming "admin" is no longer possible.
● Password Policy
Shows which password policy is being used.
– High
Password length: at least 8 characters, maximum 128 characters
At least 1 uppercase letter
At least 1 special character
At least 1 number
– Low
Password length: at least 6 characters, maximum 128 characters
You configure the password policy on the page "Security > Passwords > Options".
● Password
Enter the password. The strength of the password depends on the set password policy.
The following characters are not permitted: § ? " ; : ß \
● Password Confirmation
Enter the password again to confirm it.
● Role
Select a role.
You can choose between default and self-defined roles, refer to the page "Security > Users
> Roles.".
Configuring with Web Based Management
4.9 "Security" menu
SCALANCE S615 Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C388-08
255