Description
"Rule set" area
● Name
Define a unique name for the rule set. If you click the "Create" button, a new row with a
unique number is created.
The table contains the following columns:
● Select
Select the check box in the row to be deleted.
● No.
Shows the unique number of the entry.
● Name
Name of the rule set. The name can be changed if required.
● Comment
Comment that describes the rule set in more detail.
● Timeout [min]
Access is time-limited. Specify the duration of the access. If needed, the user can extend the
access time via the "Reset Timeout" button on the "User Specific Firewall" page.
"Rule Set Assignment" area
● Type
Specify which rule set will be assigned to whom. The display of the following table depends
on the selection for "Type".
– User Account
The rule set is activated through a user account.
– Digital Input
The rule set is executed by controlling the digital input. The prerequisite for this is that the
entry "Digital Input" is activated for the "Firewall" event under "System > Events >
Configuration".
The "User Account" table contains the following columns:
● User Account
Only users with the remote access "only" or "additional" are displayed.
● Role
Shows the role of the user.
● Rule set
Define the rule set that is valid for this user.
● Combined
Combines the user login with an event, e.g. the "Digital Input" event. To log in to the WBM
page for the user-specific firewall, voltage must be present at the digital input and user login
must be successful.
● Remaining Time
When this user is logged on, the remaining time for access is displayed.
● Force Deactivate
A user with administrator rights can log off the active user with this button.
Configuring with Web Based Management
4.9 "Security" menu
SCALANCE S615 Web Based Management
274
Configuration Manual, 11/2019, C79000-G8976-C388-08