4.5.18
cRSP / SRS
Note
Common Remote Service Platform (cRSP) / Siemens Remote Service (SRS) is a remote
maintenance platform via which remote maintenance access is possible.
To use the platform, additional service contracts are necessary and certain constraints must be
kept to. If you are interested in cRSP / SRS, call your local Siemens contact or visit Web page
https://support.industry.siemens.com/cs/gb/en/sc/2281
).
On this page, you configure the access data for the SRS / cRSP acc. to URI syntax. The
Uniform Resource Identifier (URI) is defined in RFC 3986.
Description
The page contains the following boxes:
● Enable DDNS for cRSP / SRS
Enable or disable the use of cRSP / SRS.
● Update Interval
Enter the time interval.
● Validate Server Certificate
When enabled, the device checks the validity of the received server certificate.
The table has the following columns:
● Index
The number of the entry.
● Select
Select the check box in the row to be deleted.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
200
Configuration Manual, 11/2019, C79000-G8976-C388-08