● Autoenrollment Interval [min]
Specify the period of time in minutes after which queries are sent to the SINEMA RC server.
With this query, the device checks whether there is a newer firmware file on the SINEMA RC
server or whether the connection settings have changed. If you enter the value 0, this
function is disabled.
● Timeout [min]
Specify the period of time in minutes. If no data exchange takes place, when this time has
elapsed the VPN tunnel is automatically terminated.
4.5.21
Configuration Backup
Configuration Package Backup
On this page, you can create backups of the configuration.
The created backups are saved in the file type "ConfigPackBackup". On the "System >
Load&Save > HTTP/TFTP/SFTP" page you can save configuration backups on your client PC
or load them from there.
Description
The page contains the following boxes:
● Name
Enter a name for the backup.
This table contains the following columns:
● Select
Select the row you want to delete.
● Name
Shows the name of the backup.
Configuring with Web Based Management
4.5 "System" menu
SCALANCE S615 Web Based Management
206
Configuration Manual, 11/2019, C79000-G8976-C388-08