Technical data
6.1 Technical specifications (SCALANCE W786C-2)
SCALANCE W786C
Operating Instructions, 07/2019, A5E03692138-12
63
Technical specifications
Permitted ambient conditions
Ambient temperature
Operation with 100 ... 240 VAC
You should also note the temperature
ranges specified in the approvals.
-40 °C to +60 °C
Maximum ambient temperature dur-
ing operation
With SFP variants depends on plug-in transceiver:
SFP992-1
+60 °C
SFP992-1LD
+55 °C
SFP992-1LH
+50 °C
SFP992-1LH+
+50 °C
SFP992-1ELH
+45 °C
Ambient temperature
During storage
-40
℃
to +70 °C
During transportation
-40 °C to +70 °C
Relative humidity
During operation
≤
95% at 25 °C, no condensation
Operating altitude
During operation
≤
2,000 m above sea level at max. 60 °C
ambient temperature
Contaminant concentration
According to IEC 60721
Degree of protection
IP code
IP65
Dimensions and weight
Dimensions
W x H x D
251 x 251 x 72 mm
Weight
Without power supply adapter
2.24 kg
With power supply adapter 12 - 24
VDC
2.4 kg
With power supply adapter 100 ...
240 VAC
2.4 kg
Installation options
Direct
Wall mounting
With additional holding plate
Mast mounting
•
Minimum mast diameter: 44 mm
•
Maximum mast diameter 178 mm
Mounting on a DIN rail
Mounting on an S7-300 standard rail
Mean time between failure (MTBF)
At 40 °C ambient temperature
36 years