Test of mechanical stability
B
Mechanical stability
Device type
SCALANCE
IEC 60068-2-6 vibration
IEC 60068-2-27 shock
X204-2
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X204-2TS
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
5 – 150 Hz: Max. 7.9 g
random
15 g, 6 ms duration
6 shocks per axis
50 g, 30 ms duration
6 shocks per axis
X204-2FM
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X204-2LD
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X204-2LD TS
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
5 – 150 Hz: Max. 7.9 g
random
15 g, 6 ms duration
6 shocks per axis
50 g, 30 ms duration
6 shocks per axis
X206-1
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X206-1 LD
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X208
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X208PRO
5 - 9 Hz 3.5 mm
9 - 150 Hz 1 g
10 cycles
15 g, 11 ms duration
6 shocks/axis
X212-2
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X212-2LD
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
X216
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X224
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
XF204
5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 6 ms duration
6 shocks per axis
SCALANCE X-200
Operating Instructions, 11/2021, C79000-G8976-C284-15
107