Type
Supply voltage with re‐
dundant connection
Rated voltage 24 VDC
Voltage range 19.2 VDC
to 28.8 VDC
Permitted voltage range
incl. total ripple 18.5 VDC
to 30.2 VDC
Power loss at 24 VDC
Current consumption at
rated voltage
Overcurrent protection
at input
PTC resettable fuse
X212-2
+
7.92 W
330 mA
1.1 A / 33 V
X212-2LD
+
7.92 W
330 mA
1.1 A / 33 V
X216
+
5.76 W
240 mA
1.1 A / 33 V
X224
+
8.40 W
350 mA
1.1 A / 33 V
XF204
+
2.64 W
110 mA
1.1 A / 33 V
XF204-2
+
5.28 W
220 mA
1.1 A / 33 V
XF206-1
+
4.08 W
170 mA
1.1 A / 33 V
XF208
+
3.12 W
130 mA
1.1 A / 33 V
X200-4P IRT
+
9.6 W
400 mA
1.1 A / 33 V
X201-3P IRT
+
8.4 W
350 mA
1.1 A / 33 V
X201-3P IRT PRO
no redundancy
7.2 W
300 mA
1.1 A / 33 V
X202-2IRT
+
6.0 W
300 mA
600 mA / 60 V
X202-2P IRT
+
7.2 W
300 mA
1.1 A / 33 V
X202-2P IRT PRO
no redundancy
7.2 W
300 mA
1.1 A / 33 V
X204IRT
+
4.8 W
200 mA
600 mA / 60 V
X204IRT PRO
no redundancy
4.8 W
200 mA
600 mA / 60 V
XF204IRT
+
4.8 W
200 mA
600 mA / 60 V
XF204-2BA IRT
1)
+
2.4 W
100 mA
2.5 A (non-replaceable
fuse F)
1) With the specified power loss and current consumption these are the values of the basic
device without plugged in bus adapters. The values change depending on the port types of the
plugged in bus adapters. Per port you need to add the following values to the values of the basic
device:
Port type
Power loss
Current consumption
RJ-45
0.6 W
25 mA
SCRJ
1.8 W
75 mA
Examples
The following table shows the power loss an current consumption as an example for the basic
device with different bus adapters:
Type
Plugged in bus adapter
Port types
Power loss
Current consump‐
tion
XF204-2BA IRT
2 bus adapter BA 2×RJ-45
4 x RJ-45
4.8 W
200 mA
2 bus adapters BA 2xSCRJ
4 x SCRJ
9.6 W
400 mA
1 bus adapter BA 2xSCRJ
1 bus adapter BA SCRJ/RJ-45
3 x SCRJ + 1 x RJ-45
8.4 W
350 mA
Technical specifications
SCALANCE X-200
84