For devices with the "PRO" supplement (degree of protection IP65)
With these devices, splitting of the cables (as above) is not permitted. The following cables are
permitted in the specified lengths:
• 0 to 55 m:
IE TP torsion cable with IE FC RJ-45 Plug 180
• 0 to 85 m:
IE FC TP marine / trailing / flexible / FRNC / festoon / food cable with IE FC RJ-45 Plug 180
• 0 to 100 m:
IE FC TP standard cable with IE FC RJ-45 plug 180
For X208PRO (degree of protection IP65/67)
With the X208PRO, splitting of the cables (as above) is not permitted either. The following cables
are permitted in the specified lengths:
• 0 to 55 m:
IE TP torsion cable with IE FC M12 Plug PRO
• 0 to 85 m:
IE FC TP marine / trailing / flexible / FRNC / festoon / food cable with IE FC M12 Plug PRO
• 0 to 100 m:
IE FC TP standard cable with IE FC M12 plug PRO
Permitted cable lengths - fiber-optic
Type
1 ‑ 50 m
980/1000 plastic optical
fiber (POF)
1 ‑ 100 m
200/230 polymer cladded
fiber (PCF)
6 dB max. permitted ca‐
ble attenuation with 3 dB
link power margin
0 ‑ 4000
Glass FO cable
62.5/125 µm glass fibers
0 ‑ 5000
Glass FO cable 50/125 µm
glass fibers
≤ 1 dB/km at 1300 nm;
600 MHz x km;
6 dB max. permitted ca‐
ble attenuation with 3 dB
link power margin
0 - 26000 m
glass FO cable
9/125 µm single mode fi‐
ber;
0.5 dB/km at 1310 nm;
13 dB max. permitted ca‐
ble attenuation with 2 dB
link power margin
X204-2
-
-
+
-
X204-2TS
-
-
+
-
X204-2FM
-
-
+
-
X204-2LD
-
-
-
+
X204-2LD TS
-
-
-
+
X206-1
-
-
+
-
X206-1LD
-
-
-
+
X212-2
-
-
+
-
X212-2LD
-
-
-
+
XF204-2
-
-
+
-
XF206-1
-
-
+
-
X200-4P IRT
+
+
-
-
X201-3P IRT
+
+
-
-
X201-3P IRT PRO
+
+
-
-
Technical specifications
SCALANCE X-200
86