Permitted ambient conditions
Note
Note the mounting position for XF and TS devices
With the following switches an ambient temperature of m40 °C is permitted if the
device is installed on a vertical rail:
• XF204
• XF208
• XF204-2
• XF206-1
• XF204IRT
• X204‑2TS
• X204‑2LD TS
Type
Operating temperature
Storage/transport tem‐
perature
Rel. humidity in op‐
eration (no conden‐
sation)
Operating altitude at max. xx
°C ambient temperature
X204-2
‑40 °C to +60 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X204-2TS
-40 °C to +70 ℃ *)
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X204-2FM
‑40 °C to +60 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X204-2LD
‑40 °C to +60 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X204-2LD TS
-40 °C to +70 °C *)
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X206-1
‑40 °C to +60 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X206-1LD
-40 °C to +60 ℃
-40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X208
-40 °C to +60 °C
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X208PRO
‑40 ℃ to +70 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X212-2
‑40 °C to +60 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X212-2LD
‑40 °C to +60 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X216
‑40 ℃ to +60 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X224
‑40 ℃ to +60 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
XF204
‑40 °C to +60 °C *)
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
XF204-2
-40 °C to +60 ℃ *)
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
XF206-1
-40 °C to +60 ℃ *)
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
Technical specifications
SCALANCE X-200
Operating Instructions, 11/2021, C79000-G8976-C284-15