Type
Operating temperature
Storage/transport tem‐
perature
Rel. humidity in op‐
eration (no conden‐
sation)
Operating altitude at max. xx
°C ambient temperature
XF208
-40 °C to +60 ℃ *)
-40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X200-4P IRT
‑25 ℃ to +40 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 35 ℃
3000 m at max. 30 ℃
X201-3P IRT
‑25 ℃ to +50 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 45 ℃
3000 m at max. 40 ℃
X201-3P IRT PRO
‑25 ℃ to +60 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X202-2IRT
‑40 °C to +60 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X202-2P IRT
‑25 ℃ to +60 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X202-2P IRT PRO
‑25 ℃ to +60 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X204IRT
‑40 °C to +70 ℃
‑40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
X204IRT PRO
‑25 ℃ to +70 ℃
‑40 ℃ to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
XF204IRT
-40 °C to +60 ℃ *)
-40 °C to +70 ℃
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
*) Note the information on the mounting position above.
Type
Plugged in bus adapter
Operating temper‐
ature
Storage/transport
temperature
Rel. humidity in
operation (no
condensation)
Operating altitude at max.
xx °C ambient temperature
XF204-2BA IRT
-
‑40 ℃ to +60 ℃
‑40 °C to +85 °C
‹ 95 %
2000 m at max. 56 ℃
3000 m at max. 50 ℃
2 bus adapter BA 2×RJ-45
1)
0 °C to +60 °C
2000 m at max. 56 ℃
3000 m at max. 50 ℃
2 bus adapters BA 2×RJ-45
(coated)
1)
‑40 ℃ to +60 ℃
2000 m at max. 56 ℃
3000 m at max. 50 ℃
2 bus adapters BA 2xSCRJ
0 °C to +50 °C
2000 m at max. 45 ℃
3000 m at max. 40 ℃
2 bus adapters BA 2xSCRJ
(coated)
-40 °C to +50 °C
(startup at -25 °C)
2000 m at max. 45 ℃
3000 m at max. 40 ℃
2 bus adapters BA SCRJ/
RJ45
1)
0 °C to +55 °C
2000 m at max. 50 ℃
3000 m at max. 45 ℃
1 bus adapter BA 2xSCRJ
1 bus adapter BA SCRJ/
RJ45
1)
0 °C to +50 °C
2000 m at max. 45 ℃
3000 m at max. 40 ℃
1 bus adapter BA 2×RJ-45
1)
1 bus adapter BA SCRJ/
RJ45
1)
0 °C to +55 °C
2000 m at max. 50 ℃
3000 m at max. 45 ℃
1 bus adapter BA 2xSCRJ
1 bus adapter BA 2×RJ-45
1)
0 °C to +50 °C
2000 m at max. 45 ℃
3000 m at max. 40 ℃
1) Bus adapters with FC interfaces have the same temperature values as bus adapters with RJ-45
interfaces.
Technical specifications
SCALANCE X-200
90
Operating Instructions, 11/2021, C79000-G8976-C284-15