Notes on SCALANCE W:
Note
With a SCALANCE W786-2, do not plug or pull an SFP transceiver during operation!
If you have questions on the use of SIMATIC NET products, please contact your Siemens sales
partner.
4.5
Using a pluggable transceiver (SCP/STP)
Figure 4-2
Plugging in a transceiver
Follow the steps below to insert a pluggable transceiver:
1. Remove the sealing plug of the pluggable transceiver.
2. Hold the pluggable transceiver so that the slight protrusion is on the right, see figure.
3. Insert the pluggable transceiver in this position in the pluggable transceiver slot until you
hear it engage.
The pluggable transceiver is then firmly secured.
4. Insert the connecting cable into the pluggable transceiver until you hear it engage.
The connecting cable is then firmly secured.
Assembling
4.5 Using a pluggable transceiver (SCP/STP)
Transceiver SFP/SFP+/SCP/STP
Operating Instructions, 10/2019, A5E02630804-13