Technical data
7
Note
Deviations of the technical specifications from the values displayed in the WBM
The values displayed can vary from the values displayed in the WBM (menu "System > Port
diagnostics", "SFP diagnostics" tab). The values stated and explained in this document are
authoritative.
7.1
SFP transceiver
LC connector technology
The attachment to Industrial Ethernet uses LC connector
technology (Lucent Connector).
Pluggable transceiver slot/
plugged in transceiver
7.1.1
SFP991-1/SFP991-1(C)
Properties
Transmission mode
100Base-FX complying with IEEE 802.3
Transmission rate
100 Mbps (Fast Ethernet)
Transmission medium
Multimode fiber-optic cable
Light source
LED/Class1-LASER "Eye safe"
Wavelength
1300 nm
Cable length (max.) *
)
At 50 µm fiber core diameter
3 km
At 62.5 µm fiber core diameter
3 km
Transmitter output (optical)
Minimum
At 50 μm
-24 dBm
At 62.5 μm
-18 dBm
Maximum
-14 dBm
Receiver input
Sensitivity min.
-31 dBm
Input power max.
-12 dBm
Transceiver SFP/SFP+/SCP/STP
Operating Instructions, 10/2019, A5E02630804-13