2.3.2
The TIM 3V-IE variants
The TIM 3V-IE is available in standard and advanced versions. The two communications
processors share the following properties:
● TIM without integrated modem, single width
● For installation as a communications processor (CP) in an S7-300
● With a TIM 3V-IE, an S7-300 CPU or a C7 control system can then handle SINAUT
communication:
– Over any SINAUT WAN with SINAUT ST7 and SINAUT ST1 partners
– Over an Ethernet-based network (WAN or LAN) with SINAUT ST7 subscribers
● It has two interfaces:
– RS-232 interface for connection of required WAN transmission equipment
– RJ-45 interface for attachment to Ethernet
● The SINAUT TD7 software is integrated on the TIM (TD7onTIM)
● Modules can be replaced without the need for a programming device
The following properties are different on the TIMs:
TIM 3V-IE
TIM 3V-IE Advanced
SINAUT communication over
RS-232
or
RJ-45
RS-232
and
RJ-45, also as
redundant transmission path
Use as
•
Station
•
Station
•
Nodes
•
Master station
Data memory
16,000 data messages
32,000 data messages
Number of S7 connections
8
20
Can be combined with other
TIMs in the rack
no
yes
Communication over MPI of the
S7-300 CPU
no
yes
The following figure shows a TIM 3V-IE.