Connecting and Switching on the Computing Unit
Release 04/02
3-20
Panel PC 670 Computing Unit, Equipment Manual
Connecting the computing unit via an adapter
An adapter is available for connecting the computing unit to the PLC with earlier
standard connecting cables.
Table 3-1
Adapters for connecting the computing unit
Interface
Connection
Connecting cable
Order No.
Adapter
6ES5 734-2BF00
COM 1 as
Computing unit to a SIMATIC S5
6ES5 731-1xxx0
15-pin
6ES5 731-6AG00
TTY port
programmable controller
6ES5 731-0xxx0
25-pin
6ES5 731-6AG00
In order to maintain a data transmission rate of 9600 bps up to a distance of 1000 m,
the receive diode is connected to ground (reference) via the connecting cable.
Note
Lengths deviating from the standard connection cable (6ES5 734-2BF00) can be
obtained using Order No. 6ES5 734-2xxx0, whereby xxx stands for the cable
length length code.
Summary of Contents for SIMATIC PC 670
Page 4: ...For your notes ...
Page 12: ...Contents Release 04 02 xii Panel PC 670 Computing Unit Equipment Manual ...
Page 132: ...Fault Diagnosis Release 04 02 6 12 Panel PC 670 Computing Unit Equipment Manual ...
Page 176: ...Distributed configuration Release 04 02 8 6 Panel PC 670 Computing Unit Equipment Manual ...
Page 194: ...Glossary Release 04 02 Glossary 6 Panel PC 670 Computing Unit Equipment Manual ...
Page 200: ...Index Release 04 02 Index 6 Panel PC 670 Computing Unit Equipment Manual ...