Fault Diagnosis
Release 11/02
6-2
SIMATIC Panel PC 870 Computing Unit, Equipment Manual
6.1
Problems When Using Non-Siemens Modules
Response
The PC crashes when booting.
Cause
The following causes are possible:
– Double assignment of I/O addresses
– Double assignment of hardware interrupts and/or DMA channels
– Signal frequencies or signal level are not observed
– Connector pin assignment other than specified
Remedy
Check the configuration of your PC:
S
If the configuration of your PC corresponds to the works default settings, please
contact your technical service department.
S
If the configuration of your PC has been changed, restore the default status; to
do so, remove all non-Siemens modules, and then restart the computer:
– If the problem persists, call the hotline.
– If the error has disappeared, the installed non-Siemens module was the
cause of the fault. Replace it with a Siemens module or consult the supplier
of the non-Siemens module.
Summary of Contents for Simatic PC Panel PC 870
Page 4: ...Chapter For your notes ...
Page 12: ...Contents Release 11 02 xii SIMATIC Panel PC 870 Computing Unit Equipment Manual ...
Page 94: ...Fault Diagnosis Release 11 02 6 10 SIMATIC Panel PC 870 Computing Unit Equipment Manual ...
Page 130: ...Hardware Information Release 11 02 7 36 SIMATIC Panel PC 870 Computing Unit Equipment Manual ...
Page 154: ...Index Release 11 02 Index 4 SIMATIC Panel PC 870 Computing Unit Equipment Manual ...