SIMATIC Rack PC 840 V2
Operating Instructions, Edition 05/2006, A5E00248055-04
12-1
Alarm, error and system messages
12
12.1
12.1
Boot error messages
During startup (the boot process), the BIOS first performs a Power On Self Test (POST) and
checks whether certain functional units of the PC are operating error-free. When an error
occurs within this phase, the BIOS outputs a tone sequence (beep code) based on the
current test result. The boot sequence is interrupted immediately if fatal errors occur.
If the POST does not return an error, the BIOS initializes and tests further functional units. In
this startup phase, the graphics controller is initialized and any error messages are output to
the screen.
The following lists the error messages from the system BIOS. For information on error
messages output by the operating system or programs, refer to the corresponding manuals.
On-screen error messages
On-screen error message
Meaning / suggestions
Address conflict
Plug and Play problem.
Contact your technical support team.
Combination not supported
Plug and Play problem.
Contact your technical support team.
IO device IRQ conflict
Plug and Play problem.
Contact your technical support team.
Invalid System Configuration
Data
Plug and Play Problem
•
Set the RESET CONFIGURATION DATA option in the
"Advanced" menu of Setup.
•
Contact your technical support team.
Allocation Error for ...
Plug and Play problem
•
Please undo the last hardware change.
•
Contact your technical support team.
System battery is dead.
Replace and run SETUP
The battery on the CPU module is defective or dead.
Contact your technical support team.
System CMOS checksum bad
Run SETUP
Call up SETUP, adjust settings and save. If this message appears
during each startup, contact your technical support team.
Failure Fixed Disk
Error accessing the hard drive.
Check the SETUP settings.
Contact your technical support team.
Keyboard error
Check whether the keyboard is properly connected.
Key seizure
Check whether a key on the keyboard has seized.