Parameter assignment and configuration
4.5 Transponder addressing
Communications module RF120C with application blocks for S7-1200 and S7-1500
Operating Instructions, 07/2013, C79000-G8976-C328-01
41
Address space of the transponder/MDS variants according to ISO 15693 for RF200, RF300 and
MOBY D
System
Addressing
16-bit hexadecimal number
Integer
RF200,
RF300,
MOBY D
MDS D139 (I-Code 1; 44 bytes)
Start address
End address
0000
002B
+0
+43
ID no.: (fixed-coded; can only be read as a whole)
Start address
Length
FFF0
0008
-16
+8
ISO-MDS (I-Code SLI; 112 bytes)
Start address
End address
0000
006F
+0
+111
ID no.: (fixed-coded; can only be read as a whole)
Start address
Length
FFF0
0008
-16
+8
ISO MDS (Tag-it HF-I; 256 bytes)
Start address
End address
0000
00FF
+0
+255
ID no.: (fixed-coded; can only be read as a whole)
Start address
Length
FFF0
0008
-16
+8
ISO MDS (my-d SRF55V10P; 992 bytes)
Start address
End address
0000
03DF
+0
+991
ID no.: (fixed-coded; can only be read as a whole)
Start address
Length
FFF0
0008
-16
+8
ISO-MDS (MB 89R118B, 2000 bytes)
Start address
End address
0000
07CF
+0
+1999
ID no.: (fixed-coded; can only be read as a whole)
Start address
Length
FFF0
0008
-16
+8