Programming via OPC UA
10.1 Supported methods/functions
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
120
Operating Instructions, 04/2020, C79000-G8976-C512-03
Additional functions
The integrated OPC UA servers of the communication modules offer additional functions and
diagnostic options as a supplement to the AutoID standard. The following table provides an
overview of the additional functions. The individual elements are described in greater detail
below the table.
Table 10- 3 Additional functions
OPC UA events
AutoIdDiagnosisEvent
Diagnostic events for the communication module
RfidLastAccessEvent
Event for the last transponder access
AutoIdLastLogEntryEvent
Event for the last log entry
AutoIdPresenceEvent
Event for the presence of transponders
OPC UA variables
ExecuteScan
Read point scans for transponders.
SimaticIdentModelVersion
Version information of the supported SIMATIC Ident OPC UA model
CommonSettings
General settings
CodeTypes
Definition of the data type for all AutoID identifiers with methods or events.
•
Variable "LastScanData"
•
Diagnostics variable "Identifier"
•
Union "ScanData"
CodeTypesRWData
Definition of the data type of the "RWData" diagnostics variable
DeviceClock
Device clock of the communication module
RfidSettings
RFID-specific settings
MinRssi
Lowest accepted RSSI value of the antenna
This function is only supported by UHF readers.
RfPower
Radiated power of the antenna
Diagnosis
Diagnostics information
Presence
Presence of transponders