Configuring
6.2 Configuration via PROFINET IO
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
56
Operating Instructions, 04/2020, C79000-G8976-C512-03
Parameter
Parameter value
Default value
Description
Diagnostics
messages
None
Hard errors
Hard/soft errors
None
With this parameter, you determine the extent
to which the reader-related diagnostic interrupt
messages are to be reported.
•
None:
No alarms are generated.
•
Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
•
Hard/soft errors:
Critical hardware faults and errors occurring
when processing commands are reported
by the S7 diagnostics.
IO mode
1)
Input
Output
IO-Link
Input
You use this parameter to specify the mode of
the I/O interface of the communication module:
•
Input:
Single digital input
•
Output:
Single digital output
•
IO-Link:
Mode for connection of an IO-Link device
with digital inputs/outputs.
1)
This parameter is only included for CI communication modules.