Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
75
The "RF power" parameter
The selectable values depend on the value specified in the parameter "Ident device /
system".
●
RF290R
–
Value range: 0.50 ... 5.00 W
–
Default value: 1.00 W
●
RF380R
–
Value range: 0.50 ... 2.00 W
–
Default value: 1.25 W
The "Transponder type" parameter
Selection of the transponders used. The selection depends on the value specified in the
parameter "Ident device / system". The following transponder types can be selected:
Ident device / system
Value (transponder types)
RF290R
ISO 15693
MDS D3xx, Infineon
RF300 general
RF380R
RF300
ISO 15693 General
MDS D3xx, Infineon
MDS D4xx, Fujitsu - 4 KB
MDS D1xx, NXP
MDS D2xx, TI
MDS D261, STM
RF300 Gen 2 general
RF380R Gen 2
RF300, MOBY E
RF300
MOBY E
RF300, MOBY E
ISO 15693
None
ISO 15693 General
MDS D3xx, Infineon
MDS D4xx, Fujitsu - 4 KB
MDS D1xx, NXP
MDS D2xx, TI
MDS D261, STM
MDS D5xx, Fujitsu - 8 KB