Configuring with the WBM
7.3 The menu items of the WBM
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
96
Operating Instructions, 04/2020, C79000-G8976-C512-03
Error counter
The following error types are read and displayed:
Table 7- 21 Error types displayed in the "Error counter" area
Displayed error types
Description
FZP
Passive error counter
This error counter is an indicator of a disturbed environment (interferences).
ABZ
Abort counter
Counter for protocol errors on the air interface for which the transponder
aborted communication.
CFZ
Code error counter
Counter for disruptions or collisions on the air interface that caused com-
munication to be disturbed.
SFZ
Signature error counter
Counter for failed signature encryptions of written blocks of data. Only rele-
vant for the transponder type "RF300".
CRCFZ
CRC error counter
Counter for failed CRC checks
ASMFZ
Error counter for problems on the interface to the host (CM/PC)
Counter for errors on the serial interface
Signal strength
AMLI
AM power indicator
Received signal strength [dB] for which amplitude modulation with the tran-
sponder was detected.
PMLI
PM power indicator
Received signal strength [dB] for which phase modulation with the tran-
sponder was detected.
Note
Error counter readings
The displayed error counter readings are counted from the last restart of the reader or the