Readers
5.1 SIMATIC RF210R
SIMATIC RF200
108
System Manual, 07/2017, J31069-D0227-U001-A9-7619
6GT2821-1AC10
•
During transportation and storage
•
-25 … +85 °C
Degree of protection to EN 60529
IP67
Shock-resistant to EN 60721-3-7, Class 7 M3
500 m/s
2
Vibration-resistant to EN 60721-3-7, Class 7 M3 200 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (
∅
x thread x L)
M18 x 1 x 83 mm
Weight
65 g
Type of mounting
2x nuts M18 x 1
Cable length for RS-422 interface, maximum
1000 m
LED display design
3-color LED
(operating voltage, presence, error)
5.1.7
Approvals
FCC information
Siemens SIMATIC RF210R (MLFB 6GT2821-1AC10) FCC ID NXW-RF210R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Note
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference
when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in
which case the user will be required to correct the interference at his own expense.