Readers
5.8 SIMATIC RF290R
SIMATIC RF200
156
System Manual, 07/2017, J31069-D0227-U001-A9-7619
6GT2821-0AC12
Permitted ambient conditions
Ambient temperature
•
During operation
•
-20 … +55 °C
•
During transportation and storage
•
-25 … +85 °C
Degree of protection to EN 60529
IP65
Shock-resistant to EN 60721-3-7, Class 7 M3
300 m/s
2
Vibration-resistant to EN 60721-3-7, Class 7 M3 20 m/s
2
Torsion and bending load
Not permitted
Design, dimensions and weight
Dimensions (W x H x D)
200 × 80 × 140 mm
Weight
1.8 kg
Type of mounting
2 x M5 screw
1.5 Nm
Cable length, maximum
•
RS-422: max. 1000 m
•
RS-232: max. 30 m
LED display design
4 LEDs
5.8.7
Approvals
FCC information
Siemens SIMATIC RF290R (MLFB 6GT2821-0AC12) FCC ID NXW-RF290R
This device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause
undesired operation.
Caution
Any changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.