Planning the RF200 system
4.3 Installation guidelines
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
59
Table 4- 22 Reduction of field data due to metal, range as %: Transponder and RF220R
Transponder
Reader without direct
metal influence
(Case a, b and d)
Reader flush-
mounted in metal
(Case c)
MDS D124
1)
Metal-free
100
94
On metal, distance 15 mm
97
89
Tag flush-mounted in metal;
distance all round 15 mm
86
83
MDS D126
1)
Metal-free
100
75
On metal, distance 25 mm
85
70
Flush-mounted in metal;
distance all round 50 mm
80
65
MDS D160
1)
Metal-free
100
89
On metal, distance 10 mm
100
89
MDS D324
1)
Metal-free
100
90
On metal, distance 15 mm
97
86
Flush-mounted in metal;
distance all round 25 mm
93
86
MDS D422
Metal-free
100
90
Flush-mounted in metal;
distance all round 0 mm
85
85
MDS D423
Metal-free
100
90
On metal, distance 0 mm
125
2)
115
2)
Flush-mounted in metal;
distance all round 10 mm
80
75
MDS D424
1)
Metal-free
100
93
On metal, distance 15 mm
96
89
Flush-mounted in metal;
distance all round 25 mm
86
82
MDS D425
Metal-free
100
90
Screwed onto metal
100
75
Flush-mounted in metal;
distance all round 25 mm
95
75
MDS D426
1)
Metal-free
100
90
On metal, distance 25 mm
90
75
Flush-mounted in metal;
distance all round 50 mm
80
70
MDS D428
Metal-free
100
94
On metal, distance 0 mm
100
94
MDS D460
1)
Metal-free
100
92
On metal, distance 0 mm
100
92
MDS D522
Metal-free
100
90
Flush-mounted in metal;
distance all round 0 mm
85
85