Substance
Test conditions
Rating
Concentration [%] Temperature [°C]
Gluconic acid
-
20 ℃
++++
Glycerine
-
60 ℃
++++
Glycol
-
60 ℃
++++
Urine
-
20 ℃
++++
Uric acid
-
20 ℃
++++
Hydroxides (ammonium...)
10%
20 ℃
++++
Hydroxides (Na–, K–)
40%
20 ℃
++++
Hydroxides (alkaline earth metal)
-
60 ℃
++++
Hypochlorites (K–, Na– among others)
-
60 ℃
++++
Iodides (K–, Na– among others)
-
60 ℃
++++
Silicic acid
-
60 ℃
++++
Cresol
Up to 90 %
20 ℃
○
Methanol
100%
40 ℃
++++
Methylene chloride
-
20 ℃
○
Lactic acid
100%
20 ℃
++
Mineral oils
-
40 ℃
++++
Nitrates (ammonium..., K– among
others)
-
60 ℃
++++
Nitroglycerin
-
20 ℃
○
Oxalic acid
-
20 ℃
++++
Phenol
1%
20 ℃
++++
Phosphates (ammonium..., Na– among
others)
60 ℃
++++
Phosphoric acid
50%
60 ℃
++++
85%
20 ℃
++++
Propanol
-
20 ℃
++++
Nitric acid
25%
20 ℃
○
Hydrochloric acid
10%
20 ℃
○
Brine
-
60 ℃
○
Sulfur dioxide
100%
20 ℃
++
Carbon disulfide
100%
20 ℃
○
Sulfuric acid
40%
20 ℃
○
Sulfurous acid
-
20 ℃
++
Soap solution
-
60 ℃
++++
Sulphates (ammonium..., Na– among
others)
-
60 ℃
++++
Sulfites (ammonium..., Na– among
others)
-
60 ℃
○
Tar, aroma-free
-
60 ℃
++++
Turpentine
-
20 ℃
++++
Trichloroethylene
-
20 ℃
○