Antennas
6.1 ANT 1
SIMATIC RF200
System Manual, 07/2017, J31069-D0227-U001-A9-7619
163
RF250R with ANT 1
Operating distance (S
a
)
RF250R with ANT 1
Limit distance (S
g
)
MDS D460
2...32
38
MDS D524
2...65
85
MDS D525
2...25
35
MDS D526
2...85
105
MDS D528
2...35
50
All values are in mm
6.1.5
Minimum clearances
Note
Extension of the data transmission time if distance values are undershot
If the distance values specified in the tables are undershot, it is possible that the inductive
fields will be affected. In this case, the data transmission time can increase unpredictably or
a command is aborted with an error.
For this reason, please observe the values in the tables.
Minimum distances from transponder to transponder (without multitag mode)
Table 6- 4
Minimum distances transponder edge to transponder edge
MDS D423 /
MDS D425
MDS D126 / MDS D160 /
MDS D165 / MDS D200 /
MDS D339 / MDS D426 /
MDS D428 / MDS D460
MDS D100 / MDS D124 /
MDS D139 / MDS D 261 /
MDS D400 / MDS D424
RF250R with ANT 1
≥
120 mm
≥
150 mm
≥
240 mm