Readers
5.6 SIMATIC RF685R
SIMATIC RF600
222
System Manual, 06/2019, J31069-D0171-U001-A22-7618
6GT2811-6CA10-xAA0
Channel spacing
•
ETSI
•
600 kHz
•
FCC
•
500 kHz
•
CMIIT
•
250 kHz
•
ARIB (STD-T106)
•
1200 kHz
Modulation methods
ASK: DSB modulation & PR-ASK modulation
encoding, Manchester or Pulse Interval (PIE)
Multitag capability
Yes
Typical transmission time per byte
•
Write access
•
2 ms
•
Read access
•
0.15 ms
Supply voltage
24 V DC (20 ... 30 V DC)
2)
Maximum permitted current consumption
2 A
Maximum permitted current consumption via
DI/DQ interface
1 A
3)
Current consumption (on standby), typical
•
20 V input voltage on the reader
•
220 mA / 4.4 W
•
24 V input voltage on the reader
•
190 mA / 4.5 W
•
30 V input voltage on the reader
•
150 mA / 4.5 W
Current consumption (at 1000 mW transmit power), typical
•
20 V input voltage on the reader
•
450 mA / 9.0 W
•
24 V input voltage on the reader
•
380 mA / 9.1 W
•
30 V input voltage on the reader
•
300 mA / 9.6 W
Current consumption (at 2000 mW transmit power), typical
•
20 V input voltage on the reader
•
610 mA / 12.2 W
•
24 V input voltage on the reader
•
500 mA / 12.0 W
•
30 V input voltage on the reader
•
410 mA / 12.3 W
Interfaces
Antenna connectors
1x RP-TNC
Power supply
1x M12 (8-pin)
DI/DQ interface
1x M12 (12-pin)
Digital inputs
4
Digital outputs
4
Ethernet interface
2x M12 (4-pin), 100 Mbps