Transponder
7.2 SIMATIC RF630L Smartlabel
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
373
6GT2810-2AE80-0AX2 6GT2810-2AE81-0AX1
Permitted ambient conditions
Ambient temperature
•
In operation, during write/read access
•
-25 … +85 °C
•
-25 … +85 °C
•
In operation, outside write/read access
•
-25 ... +85 °C
Special feature:
at +130 °C: Storage
retention tested for
30 minutes
•
-25 ... +85 °C
Special feature:
starting at +140 °C:
No processing pos-
sible
at -40 °C and +160
°C: Storage reten-
tion tested for 90
minutes
•
During transportation and storage
•
+5 ... +25 °C
3)
Distance from metal
Not suitable for mounting directly on metal
Degree of protection
IP67
4)
Resistance to mechanical stress
Torsion and bending stress conditionally permis-
sible
Design, dimensions and weight
Dimensions (L x W x D)
105 (±1) × 25 (±1) × 0.3
mm
90 (±0.5) × 30 (±0.5) ×
0.3 mm
Weight
Approx. 1 g
1)
The EPC memory has a default size of 96 bits. If necessary, the EPC memory size can be
expanded to 480 bits in increments of 16 bits at the cost of the user memory.
2)
The information relates to the maximum read range. You can find more information on
ranges in the section "Minimum distances and maximum ranges (Page 55)".
3)
For more information, refer to the section "Storage and transportation roll goods
(Page 363)".
4)
When affixed and if the ambient conditions are adhered to (operating temperature -25 ...
+85 °C).