Transponder
7.5 SIMATIC RF610T
SIMATIC RF600
System Manual, 06/2019, J31069-D0171-U001-A22-7618
389
6GT2810-2BB80
Mechanical specifications
Material
PVC
Silicone-free
Yes
Color
White
Antenna material
Aluminum
Type of antenna
Shortened dipole
Printing
Can be printed using heat transfer technique
Permitted ambient conditions
Ambient temperature
•
In operation, during write/read access
•
-25 ... +85 °C
•
In operation, outside write/read access
•
-40 ... +85 °C
•
During transportation and storage
•
-40 … +85 °C
Distance from metal
Not suitable for mounting directly on metal
Degree of protection
IP67
Resistance to mechanical stress
Torsion and bending stress conditionally permis-
sible
Shock-resistant according to DIN EN 60721-3-7,
Class 7 M3
100 g
2)
Vibration to EN 60068-2-6
50 g
2)
Design, dimensions and weight
Dimensions (L x W x D)
86 × 54 × 0.6 mm
Weight
3 g
1)
The information relates to the maximum read range. You will find more information on
ranges in the section "Minimum distances and maximum ranges (Page 55)".
2)
The values for shock and vibration are maximum values and must not be applied
continuously.
Note
Effects of temperatures > 70 °C
Note that in temperature ranges > 70 °C, the transponder can become slightly deformed.
However, this has no effect on the transponder function.