10.1.4
Safety Information
WARNING
Danger to life
It is not permitted to open the device or to modify the device.
The following must also be taken into account:
•
Failure to observe this requirement shall constitute a revocation of the CE approval, UL
certification for the US and Canada as well as the manufacturer's warranty.
•
For installation of the power supply, compliance with the DIN/VDE requirements or the
country-specific regulations is essential.
•
The area of application of the power supply unit is limited to "Information technology
equipment" within the scope of validity of the EN 60950/VDE 0805 standard.
•
When the equipment is installed, it must be ensured that the mains socket outlet is
freely accessible.
•
Within the operating temperature range of the power supply unit, above an ambient
temperature of +25 °C, very high temperatures (max. approx. +81.5 °C at an ambient
temperature of +70 °C) can occur on the housing due to the internal heating of the
device. In this case, make sure that the housing is covered in order to protect people
from coming into contact with the hot housing. Adequate ventilation of the power supply
must be maintained under these conditions.
Note
Operating range und use of the wide-range power supply unit
The wide-range power supply unit must only be used for SIMATIC products in the
specifically described operating range and for the documented intended use.
NOTICE
Liability
If the wide input range power supply for SIMATIC RF systems is connected to third-party
products, the end user is responsible and liable for operation of the system or end product
that includes the wide input range power supply for SIMATIC RF systems.
Note the conditions specified in the UL approval.