System diagnostics
9.1 Diagnostics via the LED displays of the reader
SIMATIC RF600
472
System Manual, 06/2019, J31069-D0171-U001-A22-7618
9.1.2
Diagnostics via LED operating display
The operating states of the reader are displayed by the "RUN/STOP", "ERROR",
"MAINTENANCE" and "PRESENCE" LEDs. The LEDs can adopt the colors green, red or
yellow and the statuses off , on , flashing :
Table 9- 1
Display of operating statuses
R/S
ER
MAINT
1)
PRE
2)
Meaning
The device is turned off.
The device is starting up.
--
--
The device is ready for operation. The connection to the application
(XML, OPC UA, controller) is not established.
There may be an error.
--
--
The device is ready for operation but there is an error.
--
--
The device is ready for operation. The connection to the application
(XML, OPC UA, controller) is established.
--
--
The device is working.
•
STEP 7, Ethernet/IP: The "writeconfig" command was received.
•
XML application: The "hostGreeting" command was received.
•
OPC UA: Connection to the client is established.
Flash test for reader identification.
--
--
--
There is an error. You will find more information on error messages in
the section "XML/PLC error messages (Page 473)".
--
--
--
The network load too high. The functioning of the device is being dis-
turbed due to receiving too many network packets.
--
--
--
The antenna is switched on. There is no transponder in the antenna
field.
--
--
--
There is at least one transponder in the antenna field.
--
--
--
One or more transponders have been detected as valid.
1)
Not present on the RF650R.
2)
Not present on the RF680R/RF685R.
--: Not relevant