background image

 

 

   

Legal information 
Warning notice system 

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent 

damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert 

symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are 

graded according to the degree of danger. 

DANGER 

 

indicates that death or severe personal injury will result if proper precautions are not taken. 

 

WARNING 

 

indicates that death or severe personal injury may result if proper precautions are not taken. 

 

CAUTION 

 

with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. 

 

CAUTION 

 

without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. 

 

NOTICE 

 

indicates that an unintended result or situation can occur if the corresponding information is not taken into 

account. 

If more than one degree of danger is present, the warning notice representing the highest degree of danger will 

be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to 

property damage. 

Qualified Personnel 

The device/system may only be set up and used in conjunction with this documentation. Commissioning and 

operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes 

in this documentation qualified persons are defined as persons who are authorized to commission, ground and 

label devices, systems and circuits in accordance with established safety practices and standards. 

Proper use of Siemens products 

Note the following: 

WARNING 

 

Siemens products may only be used for the applications described in the catalog and in the relevant technical 

documentation. If products and components from other manufacturers are used, these must be recommended 

or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and 

maintenance are required to ensure that the products operate safely and without any problems. The permissible 

ambient conditions must be adhered to. The information in the relevant documentation must be observed. 

Trademarks 

All names identified by ® are registered trademarks of the Siemens AG. The remaining trademarks in this 

publication may be trademarks whose use by third parties for their own purposes could violate the rights of the 

owner. 

Disclaimer of Liability 

We have reviewed the contents of this publication to ensure consistency with the hardware and software 

described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the 

information in this publication is reviewed regularly and any necessary corrections are included in subsequent 

editions. 

 

 

Siemens AG 
Industry Sector 
Postfach 48 48 
90026 NÜRNBERG 
GERMANY 

 J31069-D0186-U001-A4-7618  
Ⓟ 06/2009 

Copyright © Siemens AG 2006, 
2007, 2008, 2009. 
Technical data subject to change

Summary of Contents for SIMATIC RF630L Smartlabel

Page 1: ...SIMATIC RF630L Smartlabel 1 SIMATIC Sensors RFID systems SIMATIC RF630L Smartlabel Operating Instructions 06 2009 J31069 D0186 U001 A4 7618 Siemens Hardware ...

Page 2: ...qualified personnel Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission ground and label devices systems and circuits in accordance with established safety practices and standards Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications described in the catalog...

Page 3: ...ontents 1 SIMATIC RF630L Smartlabel 5 1 1 Features 5 1 2 Minimum spacing between labels 6 1 3 Memory configuration for smart labels with MLFBs 00 01 02 7 1 4 Memory configuration for smart labels with MLFB 03 10 1 5 Ordering data 12 1 6 Technical data 12 1 7 Dimension drawings 15 Siemens Hardware ...

Page 4: ...Table of contents SIMATIC RF630L Smartlabel 4 Operating Instructions 06 2009 J31069 D0186 U001 A4 7618 ...

Page 5: ...MATIC RF630L transponder 6GT2810 2AB00 6GT2810 2AB01 6GT2810 2AB02 6GT2810 2AB03 Design Area of application Simple identification such as barcode replacement or supplementation through warehouse and distribution logistics right up to product identification Memory EPC 96 bits Write range 0 2 m to 5 m 0 2 m to 5 m Reading range 0 2 m to 8 m 0 2 m to 5 m Self adhesive paper labels for attaching to pa...

Page 6: ...between labels D E Figure 1 1 Minimum spacing between labels Table 1 1 Minimum spacing Minimum spacing 6GT2810 2AB00 6GT2810 2AB01 6GT2810 2AB02 6GT2810 2AB03 a 50 mm b 50 mm Please note that smart labels can also be attached one above the other The spacing between the labels attached one above the other depends on the damping characteristics of the carrier material ...

Page 7: ...ng MLFBs 6GT2810 2AB00 6GT2810 2AB01 6GT2810 2AB02 Memory banks The memory is divided logically into three different memory banks Memory bank decimal Memory type Description MemBank 102 TID Is defined by the manufacturer contains the class identifier of a tag MemBank 012 EPC Contains the EPC UID the protocol and the CRC of a tag You can write to the EPC memory area In the delivery condition the me...

Page 8: ... K K K FFHVV 3DVVZ FFHVV 3DVVZ LOO 3DVVZ LOO 3DVVZ Color Access by SIMATIC RF660R SIMATIC RF610M Read Write read Reading the memory bit The EPC ID is automatically read during the sensing cycle of the stationary or mobile reader see SIMATIC RF660R Parameterization Manual Section EPC Class 1 GEN 2 protocol settings or SIMATIC RF610M Operating Instructions In addition the TID the EPC ID the protocol...

Page 9: ... reserved memory bank can be modified using the mobile RF610M reader Using the Write function in the data editor see SIMATIC RF610M Operating Instructions Section Write tag EPC memory bank programming or modifying EPC ID The memory area Protocol Control Bit is defined by the manufacturer and should not be changed by the user The EPC ID can be programmed using the SIMATIC RF660R reader Using the ta...

Page 10: ...cording to EPC The memory of the ISO 18000 6C G2XM chip is logically divided into four different memory banks Memory bank decimal Memory type Description MemBank 112 USER User writable USER memory area MemBank 102 TID Is defined by the manufacturer contains the class identifier and serial number of a tag MemBank 012 EPC Contains the EPC data the protocol information and the CRC data of a tag You c...

Page 11: ...part of the graphic represents one word 16 bit in the memory K K K K 06 6 K K K K FFHVV 3DVVZ FFHVV 3DVVZ LOO 3DVVZ LOO 3DVVZ 0HP DQN 0HP DQN 0HP DQN 0HP DQN 7 86 5 3 5 6 59 06 6 7 6HULDO QXPEHU 7 K K K K K K 06 6 3 3URWRFRO RQWURO 5 3 K K K K K K K K 06 6 86 5 86 5 K K K K Color Access by SIMATIC RF660R SIMATIC RF610M Read Write read Figure 1 2 Representation of the RF630L memory configuration ac...

Page 12: ...00 items 2000 on one roll 1 6 Technical data Table 1 2 Mechanical data 6GT2810 2AB00 6GT2810 2AB01 6GT2810 2AB02 6GT2810 2AB03 Dimensions L x W 101 6 mm x 152 4 mm ca 4 x 6 101 6 mm x 50 8 mm ca 4 x 2 97 mm x 27 mm 54 mm x 34 mm Design Paper with integrated antenna Plastic with integrated antenna Label type Paper label Inlay Antenna material Aluminum Static pressure 10 N mm2 Material surface Paper...

Page 13: ...rope 865 868 MHz Frequency range USA 902 928 MHz Typical read distance Paper cardboard Plastic film Plastic boxes surface resistance 10 MΩ Wood dry 30 residual humidity Glass 0 2 m to 8 m 0 2 m to 8 m 0 2 m to 4 m 0 2 m to 4 m 0 2 m to 4 m 0 2 m to 5 m 0 2 m to 5 m 0 2 m to 3 m 0 2 m to 3 m 0 2 m to 3 m Typical write distance Paper cardboard Plastic film Plastic boxes surface resistance 10 MΩ Wood...

Page 14: ...c Table 1 5 Environmental conditions 6GT2810 2AB00 6GT2810 2AB01 6GT2810 2AB02 6GT2810 2AB03 Temperature range during operation 40 C 65 C up to 80 C 200 cycles Temperature range during storage The label should be stored in the range of 15 C and 25 C at a humidity of 40 to 60 Storage duration Two years determined by the shelf life of the adhesive Torsion and bending load Partially permissible Dista...

Page 15: ... 2009 J31069 D0186 U001 A4 7618 15 1 7 Dimension drawings PP PP PP PP PP PP Figure 1 3 SIMATIC RF630L 6GT2810 2AB00 dimension drawing PP PP PP PP PP PP Figure 1 4 SIMATIC RF630L 6GT2810 2AB01 dimension drawing PP PP PP PP PP PP Figure 1 5 SIMATIC RF630L 6GT2810 2AB02 dimension drawing Siemens Hardware ...

Page 16: ...TIC RF630L Smartlabel 1 7 Dimension drawings SIMATIC RF630L Smartlabel 16 Operating Instructions 06 2009 J31069 D0186 U001 A4 7618 PP PP PP PP PP PP Figure 1 6 SIMATIC RF630L 6GT2810 2AB03 dimension drawing ...