Supported methods functions
OPC UA basic methods / functions
The integrated OPC UA servers of the readers of the SIMATIC RF600 product family support
the following OPC UA basic methods / functions:
●
OPC UA server basic functions according to the "Embedded UA Server Profile" of the
OPC UA Foundation
–
As an extension of the "Embedded UA Server Profile" the "Standard Event
Subscription Server Facet".
–
As an extension of the "Embedded UA Server Profile" the "SecurityPolicy - Basic256"
–
As an extension of the "Embedded UA Server Profile" the "SecurityPolicy - Basic
256Sha256"
–
As an extension of the "Embedded UA Server Profile" maximum of 5 OPC UA client
connections
●
"Full AutoID Server Facet" according to the specification "OPC Unified Architecture for
AutoID".
Each read point stands for an independent "AutoIdDevice" or "RfidReaderDevice".
●
The maximum 5 permitted OPC UA client connections are not dependent on the number
of configured read points.