Service and maintenance
12.2 Error messages
SIMATIC RF650R/RF680R/RF685R
296
Configuration Manual, 03/2018, C79000-G8976-C386-06
"ER"
LED
XML/
LED
(hex)
PLC block
(hex)
Error description
--
0x97
0xE7FE09 Command repetition is not supported.
--
0x7A 0xE7FE0A Error during the transfer of the PDU (Protocol Data Unit).
"--" means that the error is not displayed by the LEDs.
12.2.3
OPC UA error messages
The following table lists the OPC UA-specific error codes.
Table 12- 3 OPC UA error messages of the RF600 readers
XML/
LED
(hex)
OPC UA
status
AutoId
status
AutoId
text
Error description
0x13
good
7
OUT_OF_RANGE_
ERROR
Address error
The address area of the transponder has been exceeded.
Possible causes:
•
Start address of the command start has been incor-
rectly set.
•
Wrong transponder type
•
The area to be written to is write-protected.
0x1A good
3
PERMISSON_
ERROR
The transponder is read/write-protected.
0x91
good
19
RF_COMMUNICATION_
ERROR
The transponder is not responding.
0x92
good
4
PASSWORD_
ERROR
The transponder password is incorrect. Access is denied.
0x93
good
19
RF_COMMUNICATION_
ERROR
The verification of the written transponder data has failed.
0x94
good
19
RF_COMMUNICATION_
ERROR
General transponder error
0x95
good
19
RF_COMMUNICATION_
ERROR
The transponder has too little power to execute the com-
mand.
0x22
good
9
MULTIPLE_
IDENTIFIERS
More transponders are located in the transmission win-
dow than can be processed at the same time by the
reader.
0xA1 good
8
NO_
IDENTIFIER
There is no transponder with the required EPC-ID in the
transmission window or there is no transponder at all in
the antenna field.
0xA2 good
7
OUT_OF_
RANGE_ERROR
The requested data is not available.
0xA3 good
19
RF_COMMUNICATION_
ERROR
The transponder signals a CRC error.
0xA4 --
--
--
The selected antenna is not enabled.