Service and maintenance
12.2 Error messages
SIMATIC RF650R/RF680R/RF685R
298
Configuration Manual, 03/2018, C79000-G8976-C386-06
XML/
LED
(hex)
OPC UA
status
AutoId
status
AutoId
text
Error description
0xCD good
1
MISC_ERROR_
TOTAL
•
Firmware errors
Possible cause: The firmware update was not run
completely.
•
Internal communications error of the communications
module/reader
–
Connector contact problem on the communica-
tions module / reader
–
Hardware of the communications module / reader
has a defect; →
Send in communications module /
reader for repair
–
Start "INIT" after correcting the error
•
Internal monitoring error of the communications mod-
ule/reader
–
Program execution error on the communications
module / reader
–
Turn the power supply of the communications
module/reader off and on again
–
Start "INIT" after correcting the error
0x61
good
15
NOT_SUPPORTED_
BY_DEVICE
Unknown command
An uninterpretable XML command was sent to the reader
or the Ident profile sends an uninterpretable command to
the reader.
Possible causes:
•
The "AdvancedCmd" block was supplied with an in-
correct "CMD".
•
The "CMD" input of the "AdvancedCmd" block was
overwritten.
0x63
Bad
Invalid
Argument /
good
5
REGION_NOT_
FOUND_ERROR
All commands:
A parameter of an OPC UA command has an invalid
value.
"ReadTag"/"WriteTag" command:
The addressed memory area is not available in the cur-
rent transponder.
0xE1 BadInvalid
Argument
--
--
A parameter is missing.
0xE2 BadInvalid
Argument
--
--
The parameter has an invalid format.
0xE3 BadInvalid
Argument
--
--
The parameter type is invalid.
0xE4 BadInvalid
Argument
--
--
Unknown parameter.
0xE5 Bad
--
--
The command or the frame has an invalid format.
0xE6 good
1
MISC_ERROR_
TOTAL
The inventory command failed.