Appendix
A.3 Command and acknowledgement frames
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 03/2018, C79000-G8976-C386-06
335
A.3.9
EDIT-BLACKLIST
The black list is processed. The current transponder can be added, all identified
transponders added, individual transponders deleted or all transponders deleted.
Table A- 23 Command
Byte
0, 1
2, 3
4
5
6, 7
8
9
10
11
Mean-
ing
DBL
SN
CC
CI
TDB
DBN_H
DBN_L
DBL
MODE
Value
78
--
'z'
'U'
1
0
1
--
xx
Byte
12
13
14, 15
16, 17
18 ... 21
22, 23
24, 25
26
27 ... 88
Mean-
ing
SOURCE --
--
--
--
--
--
IDLENGT
H
EPC-ID
Value
0
0
0
0
0
0
0
xx
xx
Table A- 24 Reply
Byte
0, 1
2, 3
4
5
6, 7
8
9
10
Meaning
DBL
SN
CC
STATUS
TDB
DBN_H
DBN_L
DBL
Value
0
--
'z'
xx
1
--
1
0
Table A- 25 Description of the bytes
Byte
Description
11
Mode:
•
0x00 = add TagID
•
0x01 = add all "OBSERVED" transponders
•
0x02 = delete TagID
•
0x03 = delete all
12
Reserved (value = 0)
26
Length of the EPC ID:
•
0x00 = not addressed
27 ... 88
Buffer for up to 62 bytes EPC-ID