ET 200U Distributed I/O Station
EWA 4NEB 812 6087-02b
Analog Value Processing
7.1
Analog Input Modules
7-2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2
Connecting Current and Voltage Sensors to Analog Input Modules
7-3
. . . . .
Voltage Measurement with Isolated / Non–Isolated Thermocouples
7-3
. . . . .
Connection of Thermocouples with Compensa–ting Box to Module
464–8MA11/8MA21
7-5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Two–Wire Connection of Voltage Sensors
7-5
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Two–Wire Connection of Current Sensors
7-6
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of Two–Wire Transducers
7-7
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of Four–Wire Transducers
7-8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring of the Terminal Block
7-8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
More than Two Four–Wire Transducer Connections
7-8
. . . . . . . . . . . . . . . . . .
No Wire Break Detection with 6ES5 464–8ME11
7-8
. . . . . . . . . . . . . . . . . . . . .
Connection of Resistance Thermometers
7-9
. . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3
Start–Up of Analog Input Modules
7-11
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.4
Analog Value Representation of Analog Input Modules
7-16
. . . . . . . . . . . . . . . .
7.5
Analog Output Modules
7-25
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of Loads to Analog Output Modules
7-25
. . . . . . . . . . . . . . . . . . . . . .
Analog Value Representation of Analog Output Modules
7-27
. . . . . . . . . . . . . .
Figures
7-1
Voltage Measuring with Isolated Thermocouples
(6ES5 464–8MA11/8MA21)
7-4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2
Voltage Measuring with Non–Isolated Thermocouples
(6ES5 464–8MA11/8MA21)
7-4
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-3
Two–Wire Connection of Voltage Sensors
(6ES5 464–8MB11, 464–8MC11, 466–8MC11)
7-5
. . . . . . . . . . . . . . . . . . . . . . .
7-4
Two–Wire Connection of Current Sensors (6ES5 464–8MD11)
7-6
. . . . . . . . .
7-5
Connection of Two–Wire Transducers (6ES5 464–8ME11)
7-7
. . . . . . . . . . . .
7-6
Connection of Four–Wire Transducers (6ES5 464–8ME11)
7-8
. . . . . . . . . . . .
7-7
Wiring Method for PT 100 (6ES5 464–8MF11/8MF21)
7-9
. . . . . . . . . . . . . . . .
7-8
Wiring Possibilities for Input Modules (6ES5 464–8MF11)
7-10
. . . . . . . . . . . . .
7-9
Load Connection via a Four–Wire Circuit (6ES5 470–8MA11,
6ES5 470–8MD11)
7-26
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-10
Connection via a Two–Wire Circuit
(6ES5 470–8MB11, 6ES5 470–8MC11)
7-27
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7