Flexible automation concepts
10.2 Configuration control (option handling)
Automation system
218
System Manual, 12/2017, A5E03461182-AE
Error messages
In case of error, the WRREC instruction returns the following error messages via the
STATUS block parameter:
Table 10- 9 Error messages
Error code
Meaning
80B1
H
Invalid length; the length information in data record 196 is not
correct.
80B5
H
Configuration control parameters not assigned.
80E2
H
Data record was transferred in the wrong OB context. The data
record must be transferred in the startup program.
80B8
H
Parameter error
Reasons for a parameter error are:
•
Incorrect block ID in the header (not equal to 196)
•
Invalid version identifier in the header
•
A reserved bit was set
•
A station master slot was assigned an invalid slot in the station
option
•
Multiple slots in the station master are assigned to the same
slot in the station option
•
For shared device on submodule level: violation of defined
restrictions
Summary of Contents for Simatic S7-1500/ET 200MP