System overview
3.8 Technology functions
Automation system
80
System Manual, 12/2017, A5E03461182-AE
Benefits
Technology modules for counting, measuring and position detection offer you the following
advantages:
●
fast and timely detection of events with fine resolution for high productivity and product
quality
●
hardware-level signal processing for rapid counting, measurement and position detection
for a variety of transducers
●
simple setup and commissioning of the technology functions in the TIA Portal
●
can be used centrally in SIMATIC S7-1500 and in ET 200MP distributed I/O system
●
quick response thanks to different hardware interrupts
3.8.5
Technology module for time-based IO
Extremely high requirements on precision and speed can be met with time-based IO
modules - regardless of the performance of the controller and the fieldbus. Time-based IO
modules ensure that signals are output with a precisely defined response time. The I/O
signals are processed on a time basis.
The table below shows the main features of the technology module for time-based IO. In
conjunction with the "Output cam" and "Cam track" technology objects, the TM Timer DIDQ
16x24V ensures highly accurate cam output. In conjunction with the "Measuring input"
technology object, the TM Timer DIDQ 16x24V ensures highly accurate detection of passing
products.
Short designation
TM Timer DIDQ 16x24V
Article number
Manual
Connectable encoders
24 V incremental encoder with signals A and B
24 V pulse encoder with a signal
Max. count frequency
200 kHz with quadruple evaluation
Integrated DI
Up to 8 DIs with the following functions:
•
Up to 2 time stamps per cycle (resolution 1 µs)
•
32x oversampling
•
Counting function up to 50 kHz
•
Incremental encoder acquisition with 2 phase-shifted tracks
•
Configurable input filter to suppress interference
Integrated DQ
Up to 16 DQs with the following functions:
•
Up to 2 time stamps per cycle (resolution 1 µs)
•
32x oversampling
•
Pulse-width modulated output
•
Configurable substitute values per DQ
Diagnostic interrupt
X
Hardware interrupt
---
Isochronous mode
X (required for the time stamp and oversampling functions)