3-17
S7-200 Programmable Controller, CPU 210
C79000-G7076-C235-01
Refer to Figure 3-17 and follow these steps to enter the output coil that ends the first rung of
the first network:
1. Select “Output Coils” from the family listing and select “Set” from the instruction listing.
2. Type either the symbolic name
Alarm_Bit
or the absolute address
M0.1
in the
highlighted area.
3. Pressing ENTER highlights the “number of points” field (located underneath the output
coil). Press ENTER to accept the default value of 1. (The CPU 210 allows only one point
to be set or reset by any one Set or Reset instruction.)
4. Move the cursor to the position below the first contact.
Output Coils
Set
Network 1
F4
F5
F8
F7
F6
F10
F3
F2
Sound the alarm!
“Panic_Alarm”
Reset
Output
Set
Output Coils
Set
Network 1
F4
F5
F8
F7
F6
F10
F3
F2
Sound the alarm!
“Panic_Alarm”
S
1
Q0.0
Enter the address:
M0.1
or
Alarm_Bit
Output Coils
Set
Network 1
F4
F5
F8
F7
F6
F10
F3
F2
Sound the alarm!
“Panic_Alarm”
S
1
“Alarm_Bit”
Position the cursor
below the first contact.
Select “Output Coils”
from the family listing.
Select “Set” from the
instruction listing.
Figure 3-17 Entering the Output Coil
Getting Started with a Sample Program
Summary of Contents for Simatic S7-200 CPU 210
Page 10: ...x S7 200 Programmable Controller CPU 210 C79000 G7076 C235 01 Contents ...
Page 116: ...A 16 S7 200 Programmable Controller CPU 210 C79000 G7076 C235 01 CPU 210 Data Sheets ...
Page 126: ...F 2 S7 200 Programmable Controller CPU 210 C79000 G7076 C235 01 CPU 210 Order Numbers ...
Page 138: ...Index 12 S7 200 Programmable Controller CPU 210 C79000 G7076 C235 01 Index ...