System Manual, 04/2011 

Summary of Contents for SIMATIC WinCC V11

Page 1: ...SIMATIC HMI WinCC V11 WinCC Runtime Professional Readme System Manual 04 2011 Special considerations for Windows 7 1 Installation 2 Runtime 3 ...

Page 2: ...he relevant documentation for the specific task in particular its warning notices and safety instructions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper use of Siemens products Note the following WARNING Siemens products may only be used for the applications des...

Page 3: ...dme System Manual 04 2011 3 Table of contents 1 Special considerations for Windows 7 5 2 Installation 7 3 Runtime 9 3 1 Notes on operation in Runtime 9 3 2 Notes on operation of Runtime Professional 10 3 3 Communication 13 Index 15 ...

Page 4: ...Table of contents WinCC Runtime Professional Readme 4 System Manual 04 2011 ...

Page 5: ...CC Runtime Professional or WinCC Runtime Advanced a user must be a member of the automatically created group Siemens TIA Engineer Working with standard user rights If you are working with standard user rights in Windows 7 User Account Control UAC cannot be disabled The User Account Control is enabled in Windows 7 by default For more information on the User Account Control refer to the online help ...

Page 6: ...t Windows7 CRL_Check DisableCRLCheck_LocalSystem cmd DisableCRLCheck_CurrentUser cmd 1 Run the DisableCRLCheck_LocalSystem cmd file with administrator rights Select the command Run as administrator from the shortcut menu of the file 2 Reboot the PC If the problem persists follow these steps 1 Double click the file and run the DisableCRLCheck_CurrentUser cmd file with user rights 2 Reboot the PC NO...

Page 7: ...nal cannot be started Installation via download The supplementary installation of the WebNavigator client via download to the WebNavigator server is not permitted Hotfix for SIMATIC NET Install hotfixes for the following products SIMATIC NET CD V8 0 SP1 for Windows 7 Hotfix 1 for SIMATIC NET CD V8 0 SP1 You can find the hotfixes in the Service Support area of the Siemens website under the entry ID...

Page 8: ......

Page 9: ...rcumstances targeted attacks for example can lead to overload of the device Special characters in the user view Special characters such as are not permitted when entering a name or the password in the user view Language behavior Layout of screen keyboard The layout of the screen keyboard is not switched when the runtime language changes Tag values overwrite the maximum length You enter a character...

Page 10: ...p SQLServer2005MSSQLUser Computername WINCC The members of this group have administrator rights to the SQL server Therefore remove all Windows users from this group for whom restricted access to the WinCC database is sufficient Windows 7 Windows Server 2008 Locking key combinations If you want to lock key combinations under Windows 7 or Windows Server 2008 you must change the group policies in the...

Page 11: ...in conjunction with the startup of the Runtime of this new project You can make copies of the projects for backup purposes using the Save as command You should however continue to work with the original project Language setting for Runtime Professional With Runtime Professional illegible texts may occur during runtime if the settings in the operating system for Language for non Unicode programs do...

Page 12: ...ion Manager in the start menu 2 Click SQL Server 2005 Services in the tree 3 Check the services SQL Server WinCC SQL Server WINCCPLUSMIG and SQL Server Browser Automatic must be entered for Start Mode LocalSystem must be entered for Log On As Change the settings if necessary 4 Click SQL Server Network Configuration in the tree 5 Click Protocols for WinCC 6 Check the TCP IP protocol Enabled must be...

Page 13: ...System Manual 04 2011 13 3 3 Communication Contents Information that could not be included in the online help Communication via routing The communication from the connection partners in various subnets can be routed via the following links PROFINET PROFIBUS MPI ...

Page 14: ......

Page 15: ...Readme System Manual 04 2011 15 Index L Language behavior Screen keyboard 9 M Maximum length Tag 9 P Permitted characters User view 9 S Screen keyboard Language behavior 9 T Tag Maximum length 9 U User view Permitted characters 9 ...

Page 16: ...Index WinCC Runtime Professional Readme 16 System Manual 04 2011 ...