Ports on the video matrix
107
Siemens Building Technologies
Fire Safety & Security Products
06.2008
As IVM NT is connected via COM2, COM2 must be selected in menu option
Local
control via
:. . When used in an IVM NT system, the SIMATRIX act as a sub-
station (polling mode).
This means that each SIMATRIX in the system must be allocated an address.
Address 1 is used in this example.
The following standard parameter settings apply for the
TELEMAT/SISTORE-
NT/LMS
index card (fields in white boxes):
Fig. 85
Connecting IVM NT - TELEMAT/ SISTORE-NT/ LMS
After setting interface parameters, the system must be reset before the new settings will take effect.
Each device is supplied with the relevant device programming manual.
A *.dat file with typical settings is supplied with the SIMATRIX as standard. This file
must be enabled before it takes effect.
Parameterisation files supplied to support interface set-up:
Connection of
Dat file
GMA GMA.dat
SIPORT SIPORTQ.dat,
SIPORTS.dat
TELSCAN TEL_LIVE.dat