Basic parameters
24
Siemens Building Technologies
Fire Safety & Security Products
06.2008
Highest keyboard address
Each keyboard used in the system must be allocated a unique address. This
address is set in the operating unit using a coding switch (refer to the operating
manual). You notify the system of the highest keyboard address here. Keyboards
with a higher address than that entered here will be ignored.
Keyboards with fixed configuration
When entering the number of keyboards, these addresses are permanently
allocated to the I/O interface card (0-15) here, i.e. keyboard 1 is channel 1,
keyboard 2 is channel 2, etc.
In the case of the SIMATRIX NEO/648/164, all keyboards connected to the system need to be
permanently allocated, as only the number of devices entered will be recognised.
The factory setting for the number of keyboards is: 2
Ignoring the signal failure test
The SIMATRIX tests connection to the cameras in the system once every second.
The results of this test will be ignored if you tick the box here.
Box not ticked
(the signal failure test is not ignored):
If a camera registers as unavailable, it will not switch in during manual switching.
An error message (No Signal!) indicates that the camera is not available.
Box ticked
(the signal failure test is ignored):
Ticking the box deactivates automatic signal failure recognition. This means that
inputs without a signal may also be switched in this mode.
This may be desirable, for example when installing and setting the system up, in
order to identify inputs that are not receiving a signal.
Disabling selection of inputs without signal
This option prevents switching in blank displays both manually and when the
automatic picture cycle is active.
Memorizing of last picture configuration ( only with NEO V2 )
If this feature is selected, the last selected pictures on the video outputs are
restored after reset or power on. Otherwise the output are dark controlled after
reset.
Activating/deactivating the master relay in the event of camera signal failure
You can activate or deactivate the master relay for camera signal failure here (refer
to the operating manual).
The standard setting is
inactive
.