System real-time clock / OSD clocks
86
Siemens Building Technologies
Fire Safety & Security Products
06.2008
14
System real-time clock / OSD clocks
Fig. 62
System clock and permanent OSD clocks
14.1 OSD
clocks
The video matrix contains a real-time clock with battery back-up (system clock).
This system time can be overlaid on a maximum of eight monitors (outputs). These
overlays are described as OSD clocks.
OSD clocks can be allocated to a maximum of 8 outputs. The H and V offset
relates to the camera text of the image that is currently on display. The clock is not
displayed if the output has no signal. The date can also be displayed as an extra
option.
14.2 Real-time clock in the video matrix
The date and time of the system clock in the SIMATRIX are displayed.
Load PC time
The
Load PC time
button transfers the time in the PC to the real-time clock in the
video matrix. The clock is accurate to +- 1.53 minutes per month.