Preparation for use
7.2 Storage
1FT2 synchronous motors for SINAMICS S120
112
Configuration Manual, 03/2021, A5E50645584B AA
7.2
Storage
Note
If possible, store the motor in its original packaging.
Preserve the free shaft extensions, sealing elements, and flange surfaces with a protective
coating.
NOTICE
Seizure damage to bearings
If the motors are stored incorrectly, bearing seizure damage can occur, for example,
brinelling, as a result of vibration.
•
Comply with the storage conditions.
Storage conditions
•
Observe the warning instructions on the packaging and labels.
•
Store the motor in a dry, dust-free, and vibration-free indoor storage facility.
•
Adhere to the following values:
–
V
rms
< 0.2 mm/s
–
Max. temperatures: -15 °C to 55 °C
–
Mean relative humidity < 75%