Operation
8.4 Faults
SIMOTICS A-1FV5/1PV5 synchronous/induction motors
52
Operating Instructions, 03/2014, 610.45002.40
No.
Cause of fault
Remedial measures
L
Rotating parts are grinding
Determine cause and adjust parts
Foreign bodies within the motor
Send to manufacturer for repair
Bearing damage
Send to manufacturer for repair
M
Rotor not balanced
Decouple rotor and rebalance
N
Rotor out of true, shaft bent
Consult the manufacturer
O
Poor alignment
Align motor unit, check coupling
P
Coupled machine not balanced
Re-balance coupled motor
Q
Shocks from coupled machine
Check coupled motor
R
Imbalance originating from gearing
Adjust/repair gearing
S
Cooling water pipe / water connection
defective
Locate leaks and seal as necessary, or consult the manufacturer
If the fault still cannot be resolved after applying the measures specified above, please